This product is used in medical institutions and paired with the company's single-use microwave ablation needles. It is suitable for the ablation of solid tumors such as those in the liver, lung, breast, and benign thyroid nodules.
Centered on a solid-state source, the device features adaptive needle type recognition, real-time needle shaft temperature monitoring (with over-temperature power-off protection), and treatment data memory. It can precisely control ablation energy, balancing safety and efficacy. It is applicable for the ablation treatment of eligible solid liver tumors and benign thyroid nodules, meeting the minimally invasive treatment needs of medical institutions.
Adjustable dual-mode power/time: Liver mode (0~100W, 0~30min) and thyroid mode (0~60W, 0~20min) to meet the treatment needs of different lesions;
Digital operation and control: Touch screen + knob dual adjustment, real-time display of parameters such as power, time, and temperature for intuitive operation;
Multiple protections: Over-temperature power-off, needle type mismatch alarm, no-load output prohibition, etc., to reduce operational risks;
The solid-state microwave source adopts precision circuit integration technology, achieving triple protection against over-temperature, over-current, and empty-burn reflection; the peristaltic pump is integrated with the host to ensure the air tightness of the water cooling cycle.
A single liver tumor lesion should be < 5cm; for multiple lesions, there should be ≤ 3 lesions and each < 3cm. Additionally, the lesions must be ≥ 1.5cm away from the hepatic hilum, gallbladder, etc., and liver function should be Child-Pugh class A/B.
The supporting ablation needle models include DH-Z-A-0/A-1, DH-Z-B-0/B-1, and DH-L-C-0/C-1:
The DH-Z-A series is suitable for benign thyroid nodules and liver tumors (ultrasound-guided).
The DH-Z-B series is suitable for liver tumors (ultrasound-guided).
The DH-L-C series is suitable for liver tumors (CT-guided).
First, check whether the peristaltic pump is turned on and whether the cooling cycle channel is blocked. If the peristaltic pump is faulty or the channel is blocked, turn off the device, replace the peristaltic pump component or clear the channel. If the issue persists, contact the manufacturer's after-sales service.
Danhui Medical's steep pulse electric field ablation technology, with a smarter energy platform, provides safer and more thorough solutions for electrophysiological minimally invasive interventional surgeries.